KIU6LSOH500BQ
EAN: 5904204406284
High flammability category 6 U/UTP data communication cable by Q-LANTEC. Made of solid copper, without the addition of other metals. In production, we do not use any additives that can mimic the compliance of certain parameters with the requirements of industry standards under certain conditions. Transmission parameters meet the requirements of category 6 to the full extent. The cable is dedicated for LAN and IP CCTV video surveillance applications, supports PoE requirements. Cables of this type are designed for indoor horizontal and vertical installations. All Q-LANTEC cables remain compliant with the CPR directive on the classification of construction products for fire resistance and defining test methods for cables intended for installation in buildings.
| Category | 6 |
|---|---|
| Class | E (250MHz standard) |
| AWG cross section | 4x2x24AWG |
| Conductors | single-wire copper with diameter of 0.511mm (24AWG) |
| Insulation | polyethylene |
| CPR fire classification (Euroclass) | B2ca |
| Center | 4 pairs twisted on a cross-shaped core insert |
| Screen | none |
| Coating | halogen-free flame-retardant material with limited smoke and corrosive gases (LSOH/FRNC) |
| PoE | 802.3 bt |
| Color | gray |
| DC resistance loop | ≤ 93.8 Ω /km |
| Alternating resistance | ≤ 2% |
| Insulation resistance (500V) | ≥ 5000 MΩ *km |
| Capacitive reactive resistance at 800 Hz | nom. 48 nF/km |
| Variable reactive capacitive resistance | ≤ 1500 pF/km |
| Characteristic apparent resistance (1-1000MHz) | (100 ± 15) Ω |
| Nominal velocity of propagation (NVP) | 69%. |
| Delayed propagation | Nominally ≤ 535 ns/100m |
| Delay angle | Nominally ≤ 20 ns/100m |
| DC installation tester, 1 min (core) | 1000 V |
| Bending radius | 4 x outer ø |
| Max. pulling force | 80 N |
| Temperature range during use | -30°C to +75°C |
| Temperature range during installation | 0°C to +50°C |
| Outer diameter | 5.8 mm |
| Weight kg/km | 45 |
| Packing | spool (500m) |